Product Details:
|
Sine Force: | 50 KN (5000 Kg.f) | Max Acceleration: | 83g (sine) / 60g (random) |
---|---|---|---|
Max Velocity: | 2 M/s | Frequency Range: | 5-2500 Hz |
Max Displacement: | 100 Mm | Warranty: | 12 Months |
Highlight: | shaker testing device,vibration table testing equipment |
Random Vibration Test Machine For Aerospace Meet NASA-STD-7001A
Vibration Test Systems
EV series of electromagnetic vibration testing system simulate the vibration environment under the laboratory condition, and test the impact strength as well as reliability of various vibration test applications. In the laboratory, with the aid of vibration testing system, simulations of reproduction of sinusoidal, random, resonant search and dwell, classical shock and road models, etc. can be achieved. It is essential for product quality assurance, new product research and deve
Technical Specifications
Air Cooled Vibration Test System 50kgf-1100kgf | ||||||||||
Model | EV1005 | EV101 | EV202 | EV203 | EV204 | EV206 | EV207 | EV210 | EV210B | EV310 |
Amplifier Model | PA501EF | LPA102EF | LPA202EF | LA3K | LA4K | LA6K | LA7K | LA10K | ||
Shaker Model | A005S12 | A01S12 | A02S12 | A03S15 | A04S15 | A06S20 | A07S23 | A11S24 | A11S34 | A11T24 |
Rated Sine Force(KN/Kgf) | 0.55/55 | 1/100 | 2/200 | 3/300 | 4 /400 | 6 /600 | 7 /700 | 11/1100 | ||
Rated Shock Force(KN/Kgf) | 1/100 | 2/200 | 4/400 | 6/600 | 8 /800 | 12 /1200 | 14 /1400 | 22/2200 | ||
Frequency Range(Hz) | 5-6000(10K) | 5-6000 | 5-4500 | 5-4500 | 5-4000 | 5-4000 | 5-4000 | 5-3000 | 5-3000 | 5-3000 |
Max. Acceleration Sine/Random(g) | 30/30 | 65/60 | 80/60 | 100/60 | 85/60 | |||||
Max. Velocity(m/s) | 1.6 | 1.8 | 2.0 | |||||||
Max. Displacement Peak-Peak(mm) | 20 | 25 | 40 | 51 | 51 | 76 | ||||
Max. Payload(kg) | 20 | 100 | 100 | 120 | 120 | 300 | 300 | 300 | 300 | 300 |
Armature Diameter(mm) | 120 | 150 | 200 | 230 | 240 | 336 | 240 | |||
Resonance Frequency (Hz)(±5%) | 5,000 | 4,700 | 3,500 | 2,900 | 2,800 | 3,000 | 3,500 | 2,500 | 2,500 | 2,500 |
Effective Moving Mass(kg) | 1.7 | 1.5 | 2.5 | 3 | 4 | 6 | 7 | 11 | 13 | |
Blower | Built-in | HB751 | B751 | B112 | B402 | |||||
Blower Power | 200W | 0.75kw | 1.1kw | 4kw | ||||||
Blower Volume Flow Rate/Pressure | 2.3m3/min ;20kpa | 11m3/min ;2.11kpa | 23m3/min ;4.7kpa | |||||||
System Power | 1kVA | 3kVA | 4.6kVA | 6kVA | 7kVA | 17kVA | 18kVA | 23kVA |
Air Cooled Vibration Test System 2000kgf -3200kgf | |||||||||
Model | EV220 | EV320 | EV222 | EV222B | EV322 | EV422 | EV232 | EV232B | EV432 |
Amplifier Model | LA20K | LA20K | LA30K | ||||||
Shaker Model | A20S32 | A20T32 | A20S34 | A20S44 | A20T34 | A20F34 | A30S34 | A30S44 | A30F44 |
Rated Sine Force(KN/Kgf) | 20/2000 | 24/2400 | 22/2200 | 32/3200 | |||||
Rated Shock Force(KN/Kgf) | 40/4000 | 45/4500 | 44/4400 | 64/6400 | |||||
Frequency Range(Hz) | 5-2700 | 5-2500 | 5-3000 | 5-3000 | 5-3000 | 5-2,800 | 5-3000 | ||
Max. Acceleration Sine/Random(g) | 90/60 | 85/60 | 100/60 | 100/60 | 90/60 | 70/60 | 100/60 | 85/60 | |
Max. Velocity(m/s) | 2.0 | ||||||||
Max. Displacement Peak-Peak(mm) | 51 | 76 | 51 | 51 | 76 | 100 | 51 | 100 | |
Max. Payload(kg) | 300 | 300 | 300 | 300 | 400 | 400 | 500 | ||
Armature Diameter(mm) | 320 | 320 | 342 | 442 | 342 | 342 | 342 | 442 | 442 |
Resonance Frequency (Hz)(±5%) | 2,200 | 2,200 | 2,600 | 2,600 | 2,700 | 2,400 | 2,500 | ||
Effective Moving Mass(kg) | 24 | 24 | 24 | 25 | 30 | 30 | 30 | 35 | |
Blower | B752 | ||||||||
Blower Power | 7.5KW | ||||||||
Blower Volume Flow Rate/Pressure | 41m3/min ;2.6kpa | ||||||||
System Power | 42kVA | 42kVA | 56kVA |
Air Cooled Vibration Test System 4000kgf -7000kgf | |||||||||||
Model | EV240 | EV240B | EV440 | EV250 | EV350 | EV450 | EV260 | EV360 | EV460 | EV370 | EV470 |
Amplifier Model | LA40K | LA50K | LA60K | LA70K | |||||||
Shaker Model | A30S34 | A30S44 | A30F44 | A50F44 | A50T44 | A50F44 | A50S44 | A50T44 | A50F44 | A70T45 | A70F45 |
Rated Sine Force(KN/Kgf) | 40/4000 | 40/4000 | 40/4000 | 50/5000 | 50/5000 | 50/5000 | 60/6000 | 70/7000 | |||
Rated Shock Force(KN/Kgf) | 80/8000 | 80/8000 | 80/8000 | 100/10000 | 100/10000 | 100/10000 | 120/12000 | 140/14000 | |||
Frequency Range(Hz) | 5-3,000 | 5-3,000 | 5-3,000 | 5-2,800 | 5-2,700 | 5-2,500 | 5-2,800 | 5-2,700 | 5-2,500 | 5-2,500 | |
Max. Acceleration Sine/Random(g) | 100/60 | 115/60 | 100/60 | 100/60 | 90/60 | 83/60 | 100/60 | 100/60 | 100/60 | 100/60 | |
Max. Velocity(m/s) | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 1.8 | 1.8 | 1.9 | 1.8 |
Max. Displacement Peak-Peak(mm) | 51 | 51 | 100 | 51 | 76 | 100 | 51 | 76/63 | 100 | 76 | 100 |
Max. Payload(kg) | 500 | 500 | 500 | 500(Optional up to 2000 ) | 500 | 500(Optional up to 2000 ) | 500 | 1000(Optional up to 2000) | 1000 | ||
Armature Diameter(mm) | 342 | 442 | 442 | 442 | 442 | 442 | 442 | 442 | 442 | 452 | 452 |
Resonance Frequency (Hz)(±5%) | 2,500 | 2,500 | 2,500 | 2,400 | 2,400 | 2,100 | 2,400 | 2,400 | 2,100 | 2,100 | 2,100 |
Effective Moving Mass(kg) | 30 | 30 | 35 | 50 | 55 | 60 | 50 | 55 | 60 | 63 | 70 |
Blower | B153 | B223 | B303 | ||||||||
Blower Power | 15kw | 22kw | |||||||||
Blower Volume Flow Rate/Pressure | 82m3/min ;7.3kpa | 82m3/min ;8.5kpa | |||||||||
System Power | 56+20kVA | 75+20kVA | 85+30kVA | 95+30kVA |
Water Cooled Vibration Test System 6000kgf -25000kgf | |||||||
Model | EVW360 | EVW390 | EVW3100 | EVW3120 | EVW3160 | EVW3200 | EVW3250 |
Amplifier Model | LA60K | LA90K | LA100K | LA120K | LA160K | LA200k | LA250K |
Shaker Model | E60T45 | E90T45 | E100T55 | E120T55 | E160T65 | E200T65 | E250T67 |
Rated Sine Force(KN/Kgf) | 60/6000 | 90/9000 | 100/10000 | 120/120000 | 160/16000 | 200/20000 | 250/25000 |
Rated Shock Force(KN/Kgf) | 120/12000 | 90/18000 | 200/20000 | 250/25000 | 320/32000 | 400/40000 | 500/50000 |
Frequency Range(Hz) | 5-2,700 | 5-2,700 | 5-2,500 | 5-2,500 | 5-2,200 | 5-2,200 | 5-2,000 |
Max. Acceleration Sine/Random(g) | 100/60 | 125/60 | 100/60 | 100/60 | 100/60 | 100/60 | 100/60 |
Max. Velocity(m/s) | 2.0 | ||||||
Max. Displacement Peak-Peak(mm) | 76/63 | ||||||
Max. Payload(kg) | 1000, (optional2,000 ) | ||||||
Armature Diameter(mm) | 450 | 450 | 550 | 550 | 650 | 650 | 670 |
Resonance Frequency (Hz)(±5%) | 2,300 | 2,300 | 2,100 | 2,100 | 1,800 | 1,800 | 1,600 |
Effective Moving Mass(kg) | 60 | 70 | 90 | 90 | 150 | 150 | 180 |
Blower | C1 | C2 | |||||
Blower Power | 100 | 100 | 100 | 100 | 220 | 220 | 220 |
Blower Volume Flow Rate/Pressure | 150L/min 0.25-0.4Mpa | 200L/min 0.25-0.4Mpa | |||||
System Power | 125 | 160 | 200 | 200 | 230 | 250 | 320 |
Meets Standards
IL-STD, DIN, ISO, ASTM, IEC, ISTA, GB, GJB, JIS, BS etc.